Guías de estudio, Notas de estudios & Resúmenes
¿Buscas las mejores guías de estudio, notas de estudio y resúmenes para ? En esta página encontrarás 21 documentos de estudio para .
All 21 resultados
Ordenador por
-
Journeyman Oil Exam Questions with Correct Answers
- Examen • 22 páginas • 2024
-
- $10.59
- + aprende más y mejor
Journeyman Oil Exam 
Questions with Correct 
Answers 
 
The use of furnace cement or other materials to seal a cracked heat exchanger or parts 
which provide closure shall be for _________ repairs only. - Answer-Temporary repairs 
If a fuel storage tank is permanently removed from service for whatever reason, the tank 
and all the piping connected to it, including the outside fill and vent piping and any 
supply piping connected to the appliance, shall be: - Answer--Emptied of all liquid 
conte...
-
Journeyman oil Exam Questions with Complete Solutions
- Examen • 14 páginas • 2024
-
- $9.49
- + aprende más y mejor
Journeyman oil Exam 
Questions with Complete 
Solutions 
 
TT terminals are normally used for? 
A. Line 1 
B. Neutral 
C. Thermostat 
D. Burner load - Answer-C. Thermostat 
The stack mount primary control must be ______ prior to use. 
A. Stepped on 
B. Put in step 
C. Reset 
D. None of the above - Answer-B. Put in step 
The ECM (electrically commuted motor) features: 
A. Quicker shut-off 
B. Quicker starting 
C. Variable speed motor capability 
D. All of the above - Answer-C. Variable speed moto...
-
Journeyman Oil Burner Technician 1&2 Oils (Up To 15 GPH) Exam Questions and Answers
- Examen • 6 páginas • 2024
-
- $11.49
- + aprende más y mejor
Journeyman Oil Burner Technician 1&2 Oils (Up To 
15 GPH) Exam Questions and Answers 
How long is the emergency replacement chimney forum good for and who's responsibility is art 
to see that it is replaced? - Answer ️️ -90 days 
What needs to be preformed before all new heat installations? - Answer ️️ -Heat loss and Load 
calculations 
a fill pipe should be how many feet from any building opening? - Answer ️️ -2 feet 
What must be done when preforming an annual tune-up on a heating...
-
NFPA 31 Standard For The Installation Of Oil-Burning Equipment 2011 Edition Questions and Answers
- Examen • 3 páginas • 2024
- Disponible en paquete
-
- $10.49
- + aprende más y mejor
NFPA 31 Standard For The Installation Of 
Oil-Burning Equipment 2011 Edition 
Questions and Answers 
Authority Having Jurisdiction (AHJ) - Answer ️️ -An Organization, Office, Or Individual 
Responsible For Enforcing The Code, For approving equipment, materials, and installation, or a 
procedure 
Boiler - Answer ️️ -A Vessel Which Water Is Heated, Steam Is Generated, SuperHeated, Or In 
Witch Any Combustion Takes Place 
High Pressure Boiler - Answer ️️ -Pressures Above 15PSI 
Low Pres...
-
NFPA 211 - Journeyman Exam Practice Test with 100% Correct Answers
- Examen • 4 páginas • 2024
- Disponible en paquete
-
- $10.49
- + aprende más y mejor
NFPA 211 - Journeyman Exam Practice Test 
with 100% Correct Answers 
The conduit conveying flue gas from the appliance to the chimney is called the _______? - 
Answer️️ -Breeching. NFPA 211 3.3.15 
A chimney cap is used to ________? - Answer️️ -Provide a protective covering for the top of 
the chimney to prevent entry of rain, snow, animals and birds and to prevent downdrafts. 
_______________ is a structure containing one or more vertical or near vertical passageways for 
conveying flue...
-
Journeyman Oil burner exam with correct answers
- Examen • 1 páginas • 2024
- Disponible en paquete
-
- $8.99
- + aprende más y mejor
Journeyman Oil burner exam with correct answers 
When a new burner is installed, what wiring must also be updated? - Answer ️️ -Breaker, 
properly rated wiring, properly installed and located emergency switch, properly installed and 
located thermal electric switch, properly installed and located service switch and properly 
installed and located low water cut off 
How long is an emergency replacement chimney forum good for and who's responsibility is it to 
see that it is replaced - Answer...
-
Journeyman Oil Maine Fuel Board Rules Exam Questions and Answers
- Examen • 18 páginas • 2024
- Disponible en paquete
-
- $12.49
- + aprende más y mejor
Journeyman Oil Maine Fuel Board Rules 
Exam Questions and Answers 
What must you do if you notice code violations in a homeowners house? - Answer ️️ -Notify 
them and recommend ways to address them 
What must be done when performing an annual tune-up on a heating system? - Answer ️️ -A 
combustion efficiency test and a copy must be posted on site 
Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must 
be brought into compliance with what re...
-
Journeyman Oil Exam Questions and Answers | 100% Correct
- Examen • 23 páginas • 2024
- Disponible en paquete
-
- $12.49
- + aprende más y mejor
Journeyman Oil Exam Questions and 
Answers | 100% Correct 
TT terminals are normally used for? 
A. Line 1 
B. Neutral 
C. Thermostat 
D. Burner load - Answer ️️ -C. Thermostat 
The stack mount primary control must be ______ prior to use. 
A. Stepped on 
B. Put in step 
C. Reset 
D. None of the above - Answer ️️ -B. Put in step 
The ECM (electrically commuted motor) features: 
A. Quicker shut-off 
B. Quicker starting 
C. Variable speed motor capability 
D. All of the above - Answer ️️...
-
Maine State Journeyman Exam up to 15gph Questions and Answers
- Examen • 8 páginas • 2024
- Disponible en paquete
-
- $12.49
- + aprende más y mejor
Maine State Journeyman Exam up to 15gph 
Questions and Answers 
How many apprentices can a journeyman directly supervise? - Answer ️️ -2 
When performing any service work on a customers heating system the licensee must notify the 
homeowner of? - Answer ️️ -Efficiency and code violations 
Can a licensed journeyman perform a cleaning on wood/oil combination unit without direct 
supervision? - Answer ️️ -No 
When installing a furnace, direct wired water heater or boiler what must be do...
-
Journeyman Oil Exam Questions and Answers | Verified & Updated| 100% Correct
- Examen • 30 páginas • 2024
- Disponible en paquete
-
- $13.49
- + aprende más y mejor
Journeyman Oil Exam Questions and Answers | 
Verified & Updated| 100% Correct 
The use of furnace cement or other materials to seal a cracked heat exchanger or parts which 
provide closure shall be for _________ repairs only. - Answer ️️ -Temporary repairs 
If a fuel storage tank is permanently removed from service for whatever reason, the tank and all 
the piping connected to it, including the outside fill and vent piping and any supply piping 
connected to the appliance, shall be: - Answer...